Urology
The urology department sees a wide range of patients with lower urinary
tract symptoms following referral from primary care into the Acute
environment for further diagnosis. Checking optimal bladder capacity
prior to uro-dynamics, Trial without Catheter (TWOC), diagnosis of
incontinence type, checking for significant post void residual volumes
forms part of this diagnosis and all of which can be supported through
the use of BladderScan®. To illustrate this, patients with benign
prostatic hyperplasia (BPH)¹, prostate cancer, spinal cord injury,
stroke, spina bifida and multiple sclerosis are examples of those
who need ongoing assessment. Without BladderScan® these patients
may be subjected to the trauma of unnecessary catheterisations and
are at risk of a developing a catheter related urinary tract infection.
¹ The worldwide BPH market alone has roughly 23 million cases,
with 20% seeking treatment (reference)
Indications / Applications
Indications for the use of the BladderScan® withing Urology are;
- Patient with a risk of urinary retention
- Patient who hasn't been able to urinate spontaneously for some
time
- Patient after removal of an indwelling catheter
- Patient who is confused and restless
- Patient who isn't been able to tell you if he or she has been
able to void
- Patient who requires bladder re-training following surgery or
bladder dysfunction
- Patient with M.S.
- Patient with Parkinson disease
Benefits for the user of BaldderScan® include;
- Reduces use of unnecessary catheterisations
- Reduces use of unnecessary disposables
- Non-invasive
- Reduces incidence of urinary tract infection and associated costs
- Easy to use
- Saves staff time
- Cost-effective
- Eliminates unnecessary trauma to patients
- Non-real time allows focussed scanning
- In house product training is aligned to KSF requirements
- Can be used by any healthcare practitioner and applied to their
clinical environment
- All products, accessories and consumables can be purchased through
NHS Logistics On-Line
Cost Analysis
Key Clinical Messages
Moore D. (2002 Journal of Nursing)
Using a portable BladderScan™ to reduce the incidence
of nosocomial Urinary Tract Infections.
This paper demonstrates the speed, ease of use, cost effectiveness
and accuracy of using a portable BladderScan to reduce the incidence
of UTI's caused by urethral catheterisation. A comparison between
catheterization and use of BladderScan is presented.
Coombes G.M. (1994 The Journal of Urology Vol. 152, 2083-2085)
The accuracy of portable ultrasound scanning in the measurement
of residual urine volume.
This study shows a mean difference between catheter volume estimate,
& true bladder volume of 25 ml. The accuracy of a BladderScan™
(BVI 2500) is as good as catheter estimations of true residual volumes
and may certainly be used as an alternative to catheterization for
the measurement & determination of residual urine volume. The
gold standard of diagnostic catheterization now can be challenged.
Ding Y. et.al. (1996 Singapore M.J. 37(4) p. 365)
Clinical Utility of a Portable Ultrasound Scanner in the
Measurement Residual Urine Volume
The mean absolute error of the scanner was 52 ml. For volumes below
200 ml and 100 ml, this was 36 ml. and 24 ml respectively. A decision
regarding whether to decompress the bladder by catheterization would
have also been correct in 86% to 89% of instances, depending on the
cut-off value of the residual volume used. In other words, the ultrasound
measurement would have been correct in 9 out of 10 clinical cases
residual urine volumes in children with neurogenic bladder
Massagli T.L. Dept of Rehabilitation Medicine, Childrens
Hospital and Medical Centre and University of Washington School of
Medicine (1989 Journal of Urology vol. 142, pp. 989)
Experience with ultrasound equipment and measurement of
urine volumes: Inter-user reliability and factors of patient position
Measurements made by an experienced examiner were compared to the
true urine volume obtained by catheterization. Correlation was highly
significant. Accuracy and precision of the ultrasound measurements
were not affected by patient position. Thus, little training is necessary
to use this instrument, interuser reliability is good, and accuracy
and precision are clinically acceptable whether patients are in the
seated or supine positions.
Marks L.S. et.al. (1997 et al Urology no 50: 341)
Three-Dimensional Ultrasound Device for Rapid Determination
of Bladder Volume
Volume determinations obtained with the bladder scan device are accurate
and reliable in adult outpatients. A special technician is not required.
The results may be attributable to use of automated planimetry and
3-D volumetry, rather than a fixed geometric formula, to custom measure
each bladder shape. According to one authority, ultrasonography has
become an important extension of the urologic examination because
it is quick, safe, non-invasive, relatively inexpensive, widely available,
accurate and reliable. These attributes, along with convenience and
ease of use, appear to apply to bladder volume determination with
the present device.
Ireton R.C. et.al. from the Departments of Urology and Rehabilitation
Medicine, University of Washington School of Medicine, Seattle, Washington
(1990 J. Urol. 143:909-911)
Bladder volume Determination using a dedicated, portable
Ultrasound Scanner
Urethral catheterization is associated with patient discomfort plus
the risks of urethral trauma and urinary tract infection. A portable
ultrasound instrument that automatically determines bladder volume
was used for 164 determinations and the digital readout correlated
with the catheterized volume (r2 equals 0.79). This instrument is
a noninvasive alternative to urethral catheterization for the determination
of bladder volume in most patients.
Fuse H. (1996 Int. Urol. and Nephrology 28 (5) pp.633-637)
Measurement of Residual Urine Volume Using a Portable
Ultrasound Instrument.
A portable ultrasound unit has been developed which offers a non invasive
procedure to determine urine volume. This study was undertaken to
evaluate the accuracy of measurements by this method. A high correlation
was demonstrated between the catheterized volume and ultrasound estimation
(r˛=0,98, p<0.0001). In patients with residual of >50 ml, the
unit could correctly identify 93%. This instrument is useful in estimating
the residual urine volume, and its application is recommended as an
alternative to catheterization.
McCliment J. (2002 Contempory LTC)
Non-invasive method overcomes incontinence.
Program retrains residents to recognize the urge to void.
Seung-June ( 2002 Int. Continence Society 32nd Annual Meeting
Heidelberg, Germany, 28-30, Oral Submission)
Accuracy of ultrasound determinations of the bladder volume
in the patients with voiding dysfunction: Are the accurate in all
ranges of possible volume?
There is still no agreement on whether the ultrasound measurements
of the bladder volume are reproducible and reliable in all ranges
of possible bladder volume. We investigate the accuracy of both portable
3D scanner and 2-D conventional equipment in estimating the selected
bladder volumes. Our results demonstrated the a 3-D hand held scanner
(BladderScan) measures bladder volume in a reproducible and accurate
manner, being superior to the 2-D stationary ultrasound. We concluded
a 3-D bladder scanner a reliable applicable in determining the wide
range of bladder volume.
Urology Literature References
- Barnard, Bill

Bladderscantm Technology - Boyle, P.

Lower Urinary Tract: The Relationship Between Lower Urinary Tract Symptoms and Health Status: the UREPIK Study - ÇEVIK, I.

Comparison Of Urethral Catheterization Versus Portable Ultrasound Scanning In The Measurement Of Post-Voiding Residual Urine Volume - Coombes, G.M.

The Accuracy Of Portable Ultrasound Scanning In The Measurement Of Residual Urine Volume. - Dicuio, M.
Usefulness of a Prevoiding Transabdominal Sonographic Bladder Scan for Uroflowmetry in Patients Involved in Clinical Studies of Benign Prostatic Hyperplasia - Ding, Y.Y.

Clinical Utility Of A Portable Ultra Sound Scanner In The Measurement Of Residual Urine Volume - Dunsmuir, W.D.

The Day-To-Day Variation (Test-Retest Reliability) Of Residual Urine Measurement - Fuse, H.

Measurement Of Residual Urine Volume Using A Portable Ultrasound Instrument - Garibaldi, R.A.
Hospital Acquired Urinary Tract Infections - Ghoniem, G.M.
Pharmacologic Therapy For Urinary Incontinence - Kelly, CE

Evaluation of voiding dysfunction and measurement of bladder volume - McCliment, J.K.
Non-Invasive Method Overcomes Incontinence - Munir, V.
Does The Use Of Volumetric Bladder Ultrasound Improve The Succes Rate Of Suprapubic Aspiration Of Urine - Oh, Seung-June
Accuracy Of Bladder Volume Determinations By Ultrasonography: Are They Accurate Over Entire Bladder Volume Range? - Roupręt, M.

Urological Practice And Use Of Bladderscan. - Thomas, A.W.
A Comparison Of Homebased Uroflowmetry And Post-Void Residual Values With Out-Patient Flow Clinic Assessment.